Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.329
Filtrar
1.
Fa Yi Xue Za Zhi ; 40(1): 15-19, 2024 Feb 25.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38500456

RESUMO

OBJECTIVES: To study the application of CE-Chirp in the evaluation of hearing impairment in forensic medicine by testing the auditory brainstem response (ABR) in adults using CE-Chirp to analyze the relationship between the V-wave response threshold of CE-Chirp ABR test and the pure tone hearing threshold. METHODS: Subjects (aged 20-77 with a total of 100 ears) who underwent CE-Chirp ABR test in Changzhou De'an Hospital from January 2018 to June 2019 were selected to obtain the V-wave response threshold, and pure tone air conduction hearing threshold tests were conducted at 0.5, 1.0, 2.0 and 4.0 kHz, respectively, to obtain pure tone listening threshold. The differences and statistical differences between the average pure tone hearing threshold and V-wave response threshold were compared in different hearing levels and different age groups. The correlation, differences and statistical differences between the two tests at each frequency were analyzed for all subjects. The linear regression equation for estimating pure tone hearing threshold for all subjects CE-Chirp ABR V-wave response threshold was established, and the feasibility of the equation was tested. RESULTS: There was no statistical significance in the CE-Chirp ABR response threshold and pure tone hearing threshold difference between different hearing level groups and different age groups (P>0.05). There was a good correlation between adult CE-Chirp ABR V-wave response threshold and pure tone hearing threshold with statistical significance (P<0.05), and linear regression analysis showed a significant linear correlation between the two (P<0.05). CONCLUSIONS: The use of CE-Chirp ABR V-wave response threshold can be used to evaluate subjects' pure tone hearing threshold under certain conditions, and can be used as an audiological test method for forensic hearing impairment assessment.


Assuntos
Perda Auditiva , Audição , Adulto , Humanos , Estimulação Acústica/métodos , Limiar Auditivo/fisiologia , Audição/fisiologia , Perda Auditiva/diagnóstico , Audiometria de Tons Puros/métodos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia
2.
Sci Rep ; 14(1): 7359, 2024 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-38548854

RESUMO

Pure-tone audiometry (PTA) is the gold standard for assessing hearing loss. However, traditional PTA tests require specialized equipment, trained personnel, and a soundproof environment. Recently, smartphone-based PTA tests have been developed as an alternative method for hearing assessment. The aim of this study was to validate the accuracy and reliability of a smartphone application-based audiometry test. This study was conducted to assess the performance of application-based audiometry from November 2021 to January 2022. Pure-tone thresholds were measured using a smartphone application-based PTA test and compared with results obtained using a traditional audiometer in a sound-treated booth. The smartphone application used in this study was the "Care4Ear (Care4ear, version 1.0.6, MIJ Co., Ltd.)". Hearing thresholds less than 35 dB HL were classified as group A, 35-64 dB HL as group B, and 65 dB HL or greater as group C for the classification of hearing levels. We evaluated the accuracy of smartphone audiometry for each group and compared the results of frequency-specific hearing tests. Additionally, we examined the results of smartphone audiometry in individuals (n = 27) with asymmetric hearing loss. Seventy subjects completed both conventional audiometry and smartphone application-based hearing tests. Among the ears assessed, 55.7% were classified as group A, while 25.7% and 18.6% were classified as group B and group C, respectively. The average hearing threshold obtained from conventional pure-tone audiometry was 37.7 ± 25.2 dB HL, whereas the application-based hearing test yielded thresholds of 21.0 ± 23.0 dB HL. A significant correlation (r = 0.69, p < 0.01) was found between the average hearing thresholds obtained from the application-based and conventional pure-tone audiometry tests. The application-based test achieved a 97.4% hit rate for classifying hearing thresholds as class A, but lower rates of 22.2% for class B and 38.5% for class C. Notably, a discrepancy was observed between the hearing threshold measured by the application and the conventional audiometry for the worse ear with asymmetric hearing. The smartphone-based audiometry is a feasible method for hearing evaluation especially in persons with normal hearing. In cases of hearing loss or asymmetric hearing loss, the results of the application-based audiometry may be inaccurate, limiting its diagnostic utility.


Assuntos
Surdez , Perda Auditiva , Humanos , Reprodutibilidade dos Testes , Limiar Auditivo , Perda Auditiva/diagnóstico , Audição , Audiometria de Tons Puros/métodos
3.
Medicina (Kaunas) ; 60(2)2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38399554

RESUMO

Background and Objectives: Granulomatosis with Polyangiitis (GPA) is a rare, autoimmune, multisystemic disease characterized by vasculitis and necrotizing granuloma that commonly affects the upper and lower respiratory tract and kidneys. Audiovestibular dysfunction in GPA diseases may have different clinical presentations. The aim of the present study was to evaluate hearing function in patients with GPA and to compare the results with a healthy control group. Materials and Methods: A total of 34 individuals participated in the study. The GPA group consisted of 14 participants, and the control group was composed of 20 healthy participants with no signs or symptoms of ear disease. The ages ranged from 18 to 65 years old, with a mean age of 43.8 years. The participants underwent a complete audiological evaluation using otoscopy, impedance audiometry, pure tone audiometry, speech audiometry-evaluation of speech thresholds, and speech recognition in quiet. Both ears were tested. All of the participants of the study were native Lithuanian speakers. Data were statistically analyzed using the Statistical Analysis System software SAS® Studio 3.8. A p value < 0.05 was regarded as statistically significant. Results: 92.85% of patients from the GPA group reported hearing-related symptoms: hearing loss, tinnitus, and fullness in the ears. The arithmetic means of all hearing thresholds at frequencies from 125 Hz to 8000 Hz were significantly higher in the GPA group. The results revealed statistically significant differences between the two groups in the Speech Detection Threshold, Speech Recognition Threshold, Speech Discomfort level, and Word Recognition Scores. Conclusions: The frequency of hearing loss, the average hearing thresholds, and speech thresholds were higher in GPA patients than in healthy individuals. The most common type of hearing loss was sensorineural. Audiological assessments should be considered during the routine evaluation of patients with GPA disease to prevent hearing-related disabilities.


Assuntos
Surdez , Granulomatose com Poliangiite , Perda Auditiva Neurossensorial , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Granulomatose com Poliangiite/complicações , Audiometria de Tons Puros/métodos
4.
J Laryngol Otol ; 138(3): 289-296, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38223940

RESUMO

OBJECTIVE: Sudden hearing loss is a common presentation to ENT. In the authors' practice, patients often wait many weeks for formal hearing testing. This study aimed to assess whether a tablet-based hearing test, hearTest, could aid clinical decision-making within secondary care ENT. METHOD: This was a multi-centre, prospective, non-randomised study to assess the feasibility, usability and accuracy of hearTest. RESULTS: In the sample, hearTest was shown to be an acceptable method of testing for hearing loss by both patients and clinicians. The 0.5-4 kHz range had an average clinical agreement rate of 95.1 per cent when compared with formal pure tone audiometry, deeming it an accurate test to diagnose hearing loss. CONCLUSION: The authors propose that hearTest can be used within ENT as a clinical decision support tool when manual audiometry is not immediately available. Within the authors' practice, hearTest is used to aid diagnosis and management of sudden sensorineural hearing loss.


Assuntos
Surdez , Perda Auditiva Neurossensorial , Perda Auditiva Súbita , Humanos , Atenção Secundária à Saúde , Estudos Prospectivos , Perda Auditiva Súbita/diagnóstico , Perda Auditiva Súbita/terapia , Audiometria de Tons Puros/métodos , Audição
5.
Int J Pediatr Otorhinolaryngol ; 176: 111838, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38168652

RESUMO

OBJECTIVE: To investigate the predictive factors of long-term hearing threshold and temporal bone development in children with congenital microtia (CM). METHODS: 74 patients (92 ears) with CM enrolled, which all had auditory brainstem response (ABR) results during infancy or toddlerhood, pure tone audiometry (PTA) and high-resolution computed tomography (HRCT) results during childhood or adolescence, and had not undergone any surgery. We compared the relationship between ABR, auditory steady-state response (ASSR), the affected side, auricular morphology, presence of external auditory canal stenosis or atresia, PTA average, mastoid pneumatization, Jarhsdoerfer scores, and wether cholesteatoma exists. RESULTS: The average age of ABR in 92 ears was 2.72 ± 3.52 years old, PTA was 7.26 ± 2.51 and HRCT was 6.91 ± 2.76 years old. ABR-AC was related to PTA average, mastoid pneumatization, Jarhsdoerfer scores, and wether cholesteatoma exists in CM. While ABR-ABG was related to all of these factors except Jarhsdoerfer score, and ABR-BC had no relationship with any of them. ASSR only showed correlation with frequencies of 1, 2 kHz and was related to Jarhsdoerfer score, with no other correlations observed. The impaired ear side showed no relevance. However, auricular morphology was related to all of these factors except wether cholesteatoma exist. External auditory canal stenosis or atresia was related to PTA average, but unrelated to mastoid pneumatization. CONCLUSION: The ABR examination in the infant stage plays a crucial role in predicting the long-term hearing and temporal bone development in patients with CM.


Assuntos
Colesteatoma , Microtia Congênita , Criança , Lactente , Adolescente , Humanos , Masculino , Animais , Pré-Escolar , Constrição Patológica , Limiar Auditivo/fisiologia , Audição , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Audiometria de Tons Puros/métodos
6.
Ear Hear ; 45(1): 94-105, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37386698

RESUMO

OBJECTIVES: An unexpectedly low word recognition (WR) score may be taken as evidence of increased risk for retrocochlear tumor. We sought to develop evidence for or against using a standardized WR (sWR) score in detecting retrocochlear tumors. The sWR is a z score expressing the difference between an observed WR score and a Speech Intelligibility Index-based predicted WR score. We retrospectively compared the sensitivity and specificity of pure-tone asymmetry-based logistic regression models that incorporated either the sWR or the raw WR scores in detecting tumor cases. Two pure-tone asymmetry calculations were used: the 4-frequency pure-tone asymmetry (AAO) calculation of the American Academy of Otolaryngology-Head and Neck Surgery and a 6-frequency pure-tone asymmetry (6-FPTA) calculation previously optimized to detect retrocochlear tumors. We hypothesized that a regression model incorporating the 6-FPTA calculation and the sWR would more accurately detect retrocochlear tumors. DESIGN: Retrospective data from all patients seen in the audiology clinic at Mayo Clinic in Florida in 2016 were reviewed. Cases with retrocochlear tumors were compared with a reference group with noise- or age-related hearing loss or idiopathic sensorineural hearing loss. Two pure-tone-based logistic regression models were created (6-FPTA and AAO). Into these base models, WR variables (WR, sWR, WR asymmetry [WRΔ], and sWR asymmetry [sWRΔ]) were added. Tumor detection performance for each regression model was compared twice: first, using all qualifying cases (61 tumor cases; 2332 reference group cases), and second, using a data set filtered to exclude hearing asymmetries greater than would be expected from noise-related or age-related hearing loss (25 tumor cases; 2208 reference group cases). The area under the curve and the DeLong test for significant receiver operating curve differences were used as outcome measures. RESULTS: The 6-FPTA model significantly outperformed the AAO model-with or without the addition of WR or WRΔ variables. Including sWR into the AAO base regression model significantly improved disease detection performance. Including sWR into the 6-FPTA model significantly improved disease detection performance when large hearing asymmetries were excluded. In the data set that included large pure-tone asymmetries, area under the curve values for the 6-FPTA + sWR and AAO + sWR models were not significantly better than the base 6-FPTA model. CONCLUSIONS: The results favor the superiority of the sWR computational method in identifying reduced WR scores in retrocochlear cases. The utility would be greatest where undetected tumor cases are embedded in a population heavily representing age- or noise-related hearing loss. The results also demonstrate the superiority of the 6-FPTA model in identifying tumor cases. The 2 computational methods may be combined (ie, the 6-FPTA + sWR model) into an automated tool for detecting retrocochlear disease in audiology and community otolaryngology clinics. The 4-frequency AAO-based regression model was the weakest detection method considered. Including raw WR scores into the model did not improve performance, whereas including sWR into the model did improve tumor detection performance. This further supports the contribution of the sWR computational method for recognizing low WR scores in retrocochlear disease cases.


Assuntos
Perda Auditiva Neurossensorial , Neoplasias , Presbiacusia , Doenças Retrococleares , Humanos , Estudos Retrospectivos , Perda Auditiva Neurossensorial/diagnóstico , Presbiacusia/diagnóstico , Audiometria de Tons Puros/métodos
7.
Ear Hear ; 45(2): 329-336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37700446

RESUMO

OBJECTIVES: To evaluate the extent of hearing loss among pottery workers in Mexico exposed to lead. DESIGN: The authors conducted a cross-sectional study including 315 adult pottery workers. Auditory function was evaluated by air conduction pure-tone audiometry (pure-tone average) and distortion-product otoacoustic emission (DPOAE) levels (amplitude and signal-to-noise ratio). Lead exposure was assessed with a single blood sample test and classified as low, medium, and high according to blood lead tertiles. Logistic regression models were calculated for the association between blood lead levels, pure-tone average, and DPOAE records. RESULTS: Median (25th-75th) blood lead levels were 14 µg/dL (7.5-22.6 µg/dL). The audiometric pattern and DPOAE records were similar across blood lead levels groups in all frequencies, and no statistically significant differences were found. Adjusted logistic regression models showed no increase in the odds for hearing thresholds >25 dB (HL) and DPOAE absence associated with blood lead levels, and no dose-response pattern was observed ( p > 0.05). CONCLUSIONS: Given the results from this cross-sectional study, no association was found between blood lead levels and hearing loss assessed with DPOAE. Future longitudinal work should consider chronic lead exposure estimates among underrepresented populations, which can potentially inform safer work practices to minimize the risk of ototoxicity.


Assuntos
Surdez , Perda Auditiva , Ototoxicidade , Adulto , Humanos , Chumbo , Ototoxicidade/etiologia , Estudos Transversais , Limiar Auditivo/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Perda Auditiva/induzido quimicamente , Audiometria de Tons Puros/métodos
8.
Ear Hear ; 45(2): 451-464, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38062570

RESUMO

OBJECTIVES: Motivated by the growing need for hearing screening in China, the present study has two objectives. First, to develop and validate a new test, called the Chinese Zodiac-in-noise (ZIN) test, for large-scale hearing screening in China. Second, to conduct a large-scale remote hearing screening in China, using the ZIN test developed. DESIGN: The ZIN test was developed following a similar procedure as the digits-in-noise test but emphasizes the importance of consonant recognition by employing the 12 zodiac animals in traditional Chinese culture as speech materials. It measures the speech reception threshold (SRT) using triplets of Chinese zodiac animals in speech-shaped noise with an adaptive procedure. RESULTS: Normative data of the test were obtained in a group of 140 normal-hearing listeners, and the performance of the test was validated by comparisons with pure-tone audiometry in 116 listeners with various hearing abilities. The ZIN test has a reference SRT of -11.0 ± 1.6 dB in normal-hearing listeners with a test-retest variability of 1.7 dB and can be completed in 3 minutes. The ZIN SRT is highly correlated with the better-ear pure-tone threshold ( r = 0.82). With a cutoff value of -7.7 dB, the ZIN test has a sensitivity of 0.85 and a specificity of 0.94 for detecting a hearing loss of 25 dB HL or more at the better ear.A large-scale remote hearing screening involving 30,552 participants was performed using the ZIN test. The large-scale study found a hearing loss proportion of 21.0% across the study sample, with a high proportion of 57.1% in the elderly study sample aged over 60 years. Age and gender were also observed to have associations with hearing loss, with older individuals and males being more likely to have hearing loss. CONCLUSIONS: The Chinese ZIN test is a valid and efficient solution for large-scale hearing screening in China. Its remote applications may improve access to hearing screening and enhance public awareness of hearing health.


Assuntos
Surdez , Perda Auditiva , Percepção da Fala , Idoso , Masculino , Humanos , Pessoa de Meia-Idade , Fala , Ruído , Perda Auditiva/diagnóstico , Audiometria de Tons Puros/métodos , Limiar Auditivo , Audição , Teste do Limiar de Recepção da Fala/métodos
9.
Ir J Med Sci ; 193(1): 383-388, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37518821

RESUMO

BACKGROUND: Subjective tinnitus is an unpleasant perception of sound without any external acoustic stimulus. It can be manifested in the form of various phantom sounds, which most often resemble ringing, whistling, squeaking, noise, chirping, or buzzing. The sounds are heard solely by the sufferer and can occur in the middle of the head, but also in the ears-on one or both sides. AIM: The aim of the study was to evaluate the hearing capacity based on audiometric threshold measurements in the frequency range of 0.125-16 kHz in patients with tinnitus. In addition, we investigated the following questions: Can high-frequency audiometry be useful in the diagnosis of tinnitus? Does hearing loss occur in an increasingly wide frequency range with age compared to the control group? Can tinnitus be considered the first symptom of the onset of high-frequency hearing loss? METHODS: The study included 99 patients, all of whom underwent pure-tone audiometry (PTA) and extended high-frequency audiometry (HFA) in the ranges of 0.125-8 kHz and 8-16 kHz, respectively. In each patient (excluding the control group), tinnitus was characterized in terms of its frequency and intensity. RESULTS AND CONCLUSION: The study concluded that tinnitus may be a symptom indicating the presence of high-frequency hearing loss as hearing loss occurs in an increasingly wider frequency range with age, so HFA should be a routine audiological test in patients with tinnitus.


Assuntos
Zumbido , Humanos , Audiometria de Tons Puros/métodos , Perda Auditiva de Alta Frequência/diagnóstico , Limiar Auditivo
10.
Clin Otolaryngol ; 49(1): 74-86, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37828806

RESUMO

OBJECTIVES: Technological advancements in mobile audiometry (MA) have enabled hearing assessment using tablets and smartphones. This systematic review (PROSPERO ID: CRD42021274761) aimed to identify MA options available to health providers, assess their accuracy in measuring hearing thresholds, and explore factors that might influence their accuracy. DESIGN AND SETTING: A systematic search of online databases including PubMed, Embase, Cochrane, Evidence Search and Dynamed was conducted on 13th December 2021, and repeated on 30th October 2022, using appropriate Medical Subject Headings (MeSH) terms. Eligible studies reported the use of MA to determine hearing thresholds and compared results to conventional pure-tone audiometry (CA). Studies investigating MA for hearing screening (i.e. reporting just pass/fail) were ineligible for inclusion. Two authors independently reviewed studies, extracted data, and assessed methodological quality and risk of bias using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. PARTICIPANTS: Adults and children, with and without diagnosis of hearing impairment. MAIN OUTCOME MEASURES: A meta-analysis was performed to obtain the mean difference between thresholds measured using MA and CA in dB HL. RESULTS: Searches returned 858 articles. After systematic review, 17 articles including 1032 participants were analysed. The most used software application was ShoeboxTM (6/17) followed by Hearing TestTM (3/17), then HearTestTM (2/17). Tablet computers were used in ten studies, smartphones in six, and a computer in one. The mean difference between MA and CA thresholds was 1.36 dB (95% CI, 0.07-2.66, p = 0.04). Significant differences between mobile audiometry (MA) and conventional audiometry (CA) thresholds were observed in thresholds measured at 500Hz, in children, when MA was conducted in a sound booth, and when MA was self-administered. However, these differences did not exceed the clinically significant threshold of 10 decibels (dB). Included studies exhibited high levels of heterogeneity, high risk of bias and low concerns about applicability. CONCLUSIONS: MA compares favourably to CA in measuring hearing thresholds and has role in providing access to hearing assessment in situations where CA is not available or feasible. Future studies should prioritize the integration of pure-tone threshold assessment with additional tests, such as Speech Recognition and Digits-in-Noise, for a more rounded evaluation of hearing ability, assesses acceptability and feasibility, and the cost-effectiveness of MA in non-specialist settings.


Assuntos
Perda Auditiva , Audição , Adulto , Criança , Humanos , Limiar Auditivo , Perda Auditiva/diagnóstico , Audiometria , Audiometria de Tons Puros/métodos , Smartphone
11.
Ophthalmology ; 131(1): 30-36, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37567417

RESUMO

PURPOSE: To better characterize the frequency and patterns of hearing dysfunction in patients who have received teprotumumab to treat thyroid eye disease. DESIGN: Noncomparative case series. PARTICIPANTS: Patients who underwent audiology testing before and after completion of teprotumumab infusions. METHODS: A review of patients who underwent audiology testing before and after completion of teprotumumab infusions was carried out. Additional audiogram testing during treatment was included when available. Hearing function was analyzed using audiogram data measuring threshold hearing levels at specific frequencies. Basic demographic data as well as information regarding otologic symptoms also were obtained and analyzed. MAIN OUTCOME MEASURES: Hearing loss demonstrated by a significant change in decibel hearing thresholds or that meets criteria for ototoxicity. RESULTS: Twenty-two patients (44 ears) were included in the study, with baseline and most recent audiology testing after treatment ranging from 84 days before to 496 days after treatment. Fifteen patients (30 ears) also underwent testing during treatment starting after the second infusion up until the day of, but before, the eighth infusion. Hearing loss after treatment met criteria for ototoxicity in 17 of the 44 ears (38.6%), with 11 of the 22 patients (50.0%) meeting criteria in at least 1 ear. The pure-tone average decibel hearing levels (HLs) across all 44 ears demonstrated hearing loss after treatment (P = 0.0029), specifically at high (P = 0.0008) and middle frequencies (P = 0.0042), but not at low frequencies (P = 0.8344). Patients who were older also were more likely to experience hearing loss after treatment (P = 0.0048). CONCLUSIONS: Audiometric data demonstrate that teprotumumab influences hearing function, most significantly at higher frequencies and in older patients. Audiometric testing is critical for counseling patients regarding teprotumumab treatment. A protocol for monitoring hearing during treatment is needed to detect and manage hearing changes associated with teprotumumab use. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Perda Auditiva , Ototoxicidade , Humanos , Idoso , Limiar Auditivo , Audiometria de Tons Puros/métodos , Perda Auditiva/induzido quimicamente , Perda Auditiva/diagnóstico , Audição
12.
Acta Otolaryngol ; 143(sup1): S30-S33, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38063331

RESUMO

Background: The preoperative evaluation of Congenital Malformation of the Middle and Outer Ear (CMMOE) is very important. Jahrsdoerfer score commonly used at present, based on CT scanning images of the temporal bone, is often unable to accurately evaluate deformity and hearing level.Aims/Objectives: To investigate and promote a straightforward and easily accessible assessment method, pure tone audiometry, for the evaluation of CMMOE.Material and Methods: A total of 223 cases (244 ears) CMMOE with hearing data were retrospectively analyzed. Among them, 180 cases (197 ears) underwent exploratory tympanoplasty with clear conditions: ossicle numbers in 136 cases (147 ears) and morphology in 128 cases (138 ears) and vestibular window development in 137 cases (146 ears), and CT scans of temporal bone in 113 cases (120 ears). 1). The correlation was analyzed between ossicle numbers, ossicle morphology, Jahrsdoerfer score groups and their corresponding Average Air-Conduction Threshold of pure tone (AACT) at 0.5-4 KHz. 2) The AACT difference is compared among the above groups respectively and between the developed and undeveloped groups of vestibular window at 0.5-4 KHz and each frequency of 0.125-8 KHz. Spearman method was used for correlation analysis (calculating coefficient r and p values). For the data followed a normal distribution, a one-way analysis of variance (ANOVA) and t-test were employed, otherwise, Kruskal Wallis multiple local rank coincidence test and Wilcoxon rank sum test were used. p <0 .05 was considered statistically significant.Results: 1) The correlation coefficients between the groups of ossicle number scores, ossicle morphology scores, Jahrsdoerfer scores and their corresponding AACT are r = -0.187 (p <0 .05), r = -0.073 (p >0 .05) and r = -0.079 (p > 0.05), respectively. 2) Comparison of AACT difference based on ossicle number or morphological scores and Jahrsdoerfer scores with p > 0.05 among all groups, respectively. The AACT difference between the developed and undeveloped vestibular window groups is 5.5 (63.5/69.0) dB HL(p < .05) at 0.5-4KHz, out of 0.125-8 KHz frequency 1, 2, 4 KHz were 5.7 (65.0/70.7) dB HL, 8.4 (60.7/69.1) dB HL and 2 (61.5/63.5) dB HL, respectively, all p < 0.05, the other frequencies with all p > 0.05.Conclusions and Significance: 1) Ossicle number was correlated with AACT, but not for ossicle morphology and Jahrsdoerfer scores. 2) There was no significant difference in AACT corresponding to ossicle number or morphology scores and Jahrsdoerfer scores groups, but the patients with undeveloped vestibular window had poorer hearing than those with developed ones. Therefore, the AACT can evaluate the development of ossicle and vestibular window, and more directly reflect the hearing level than Jahrsdoerfer score. Pure tone audiometry is simple, widely used, and easily accessible, which making it a new assessment method of CMMOE.


Assuntos
Orelha Média , Audição , Humanos , Audiometria de Tons Puros/métodos , Estudos Retrospectivos , Orelha Média/diagnóstico por imagem , Orelha Externa , Limiar Auditivo
13.
Artigo em Inglês | MEDLINE | ID: mdl-38082774

RESUMO

The behavioural nature of pure-tone audiometry (PTA) limits those who can participate in the test, and therefore those who can access accurate hearing threshold measurements. Event Related Potentials (ERPs) from brain signals has shown limited utility on adult subjects, and a neural response that can consistently be identified as a result of pure-tone auditory stimulus has yet to be identified. The in doing so challenge is worsened by the nature of PTA, where stimulus amplitude decrease to a patient's lower threshold of hearing. We investigate whether EEGNet, a compact Convolutional Neural Network, could help in this domain. We trained EEGNet on a dataset collected whilst patients underwent a test designed to mimic a pure-tone audiogram, then assessed EEGNet performance in the detection task. For comparison, we also trained Support Vector Machines (SVMs) and Common Spatial Patterns + Linear Discriminant Analysis (CSPLDA) on the same task, with the same training paradigms. The results show that EEGNet is capable of detecting hearing events with 81.5% accuracy on unseen participants, outperforming SVMs by just over 5%. Whilst EEGNet outperformed SVMs and CSPLDA, it did not, however, always show a statistically significant improvement. Further analysis of EEGNet predictions revealed that, with sufficient test repetition, EEGNet has the potential to accurately ascertain hearing thresholds. The implication of these results is for a brain-signal based hearing test for those with physical or mental disabilities that limit their participation in a PTA. While this research is promising, future research will be needed to address the complexity of test setup, the duration of testing, and to further improve accuracy.


Assuntos
Audição , Redes Neurais de Computação , Adulto , Humanos , Limiar Auditivo/fisiologia , Audiometria de Tons Puros/métodos
14.
Vestn Otorinolaringol ; 88(6): 15-21, 2023.
Artigo em Russo | MEDLINE | ID: mdl-38153888

RESUMO

OBJECTIVE: The research was aimed to assess speech intelligibility in adults after the new coronavirus infection (COVID-19), state of peripheral and central parts of auditory system and cognitive functions. MATERIAL AND METHODS: 26 people complaining about hearing loss, poor speech intelligibility and/or tinnitus after COVID-19 were examined. All the patients underwent the basic audiological assessment before COVID-19. Extended testing in patients after COVID-19 included: pure tone audiometry, impedancemetry, speech audiometry in quiet and noise (evaluation of monosyllabic words intelligibility and the Russian matrix sentence test RuMatrix), the alternating binaural speech test, the dichotic digits test and the Montreal Cognitive Assessment (MoCA). RESULTS: The most significant deviations from the normative values were obtained in the RuMatrix test and the dichotic digits test that may be due to both central auditory processing disorder and memory impairment. Low MoCA scores were obtained in 62% of patients. CONCLUSION: Deterioration of speech intelligibility after COVID-19 was revealed, both in patients with hearing loss and with normal hearing that corresponded to their complaints. It may be caused by central auditory disorder, memory impairment or cognitive status lesion. The correlation found between the results of the RuMatrix test in noise and the severity of the COVID-19 may indicate the impact of the virus on the auditory cortex.


Assuntos
COVID-19 , Perda Auditiva , Adulto , Humanos , Inteligibilidade da Fala , COVID-19/complicações , COVID-19/diagnóstico , Ruído , Audiometria de Tons Puros/métodos , Limiar Auditivo
15.
Mil Med ; 188(Suppl 6): 529-535, 2023 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-37948280

RESUMO

INTRODUCTION: U.S. Army regulations require all soldiers to undergo annual audiometric testing to maintain hearing readiness. The standard method of monitoring hearing in the DoD is via multi-person testing in sound-treated booths using the Defense Occupational and Environmental Health Readiness System-Hearing Conservation. COVID-19 significantly hindered the standard method, resulting in alarming declines in hearing readiness. In response, the Army Hearing Program initiated a pilot program to use boothless audiometers to supplement standard methods to increase hearing readiness. MATERIALS AND METHODS: Funding from the Coronavirus Aid, Relief, and Economic Security Act was used to purchase 169 boothless audiometers and increase staffing at dozens of Army Hearing Program clinics. Standard operating procedures were established for audiometric testing outside the booth using a process matching standard test parameters (i.e., test frequencies, tone characteristics, and interstimulus intervals). Additional capabilities developed to leverage this new technology during the annual hearing exam include the administration of automated contralateral masking, enhanced tinnitus screening, and hearing health education and training. RESULTS: Monitoring audiometry using boothless audiometers has been conducted for nearly 12,000 service members worldwide. Thresholds obtained via boothless audiometers are comparable to follow-up thresholds obtained from the standard test methods in the booth (mean difference 95% CI, -1.2, 0.9), and hearing readiness has returned to pre-pandemic levels at installations where this novel technology is being used regularly. CONCLUSIONS: Significant reductions in patient encounters as a direct result of the COVID-19 pandemic have led to innovative solutions leveraging boothless audiometers. While this has aided the primary mission to maintain a medically ready force, innovations from this endeavor highlight several additional improvements relative to current standards of care that should be considered for permanent inclusion in DoD Hearing Conservation Programs.


Assuntos
Militares , Pandemias , Humanos , Audiometria de Tons Puros/métodos , Audição , Audiometria , Limiar Auditivo
16.
Fa Yi Xue Za Zhi ; 39(4): 360-366, 2023 Aug 25.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-37859474

RESUMO

The qualitative, quantitative, and localization analysis of hearing loss is one of the important contents of forensic clinical research and identification. Pure-tone audiometry is the "gold standard" for hearing loss assessment, but it is affected by the subjective cooperation of the assessed person. Due to the complexity of the auditory pathway and the diversity of hearing loss, the assessment of hearing loss requires the combination of various subjective and objective audiometric techniques, along with comprehensive evaluation based on the case situation, clinical symptoms, and other examinations to ensure the scientificity, accuracy and reliability of forensic hearing impairment assessment. Objective audiometry includes acoustic impedance, otoacoustic emission, and various auditory evoked potentials. The frequency-specific auditory brainstem response (ABR), 40 Hz auditory event related potential, and auditory steady-state response are commonly used for objective hearing threshold assessment. The combined application of acoustic impedance, otoacoustic emission and ABR can be used to locate hearing loss and determine whether it is located in the middle ear, cochlea, or posterior cochlea. This article reviews the application value of objective audiometry techniques in hearing threshold assessment and hearing loss localization, aiming to provide reference for forensic identification of hearing loss.


Assuntos
Medicina Clínica , Perda Auditiva , Humanos , Reprodutibilidade dos Testes , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Perda Auditiva/diagnóstico , Audiometria de Tons Puros/métodos
17.
Environ Sci Pollut Res Int ; 30(47): 104464-104476, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37700133

RESUMO

The issue of hearing protection in the presence of noise pollution is of great importance in the fields of environmental science and clinical medicine. Currently, the clinical significance of Klotho in relation to hearing has not been revealed. The aim of this study was to examine the correlation between serum Klotho levels and Pure Tone Average (PTA) hearing thresholds among individuals in the U.S.. The analysis involved a sample of 1,781 individuals aged 20 to 69, obtained from the 2007-2012 National Health and Nutrition Examination Survey. Various methods were utilized for the analysis, including univariate and multivariate linear regression, stratified analysis, smooth curve fitting, a two-segment linear regression model, and log-likelihood ratio analysis. The results of the univariate analysis indicated that serum Klotho concentration, age, education level, hypertension, diabetes, and smoking all exhibited a significant influence on PTAs. After adjusting for potential confounding factors, it was observed that a decrease in serum Klotho was significantly associated with PTA thresholds at low frequency (ß = -0.002; 95% CI: -0.003, -0.001; P = 0.004), speech frequency (ß = -0.002; 95% CI: -0.003, -0.001; P = 0.007), and high frequency (ß = -0.002; 95% CI: -0.003, -0.001; P = 0.045). Specifically, for every 1 pg/ml decrease in serum Klotho concentration, the PTAs increased by 0.002 dB. Moreover, age and gender-specific analyses revealed significant associations. For individuals aged 59-69, a significant association was found between serum Klotho concentration and high-frequency PTA (ß = -4.153; 95% CI: -7.948, -0.358; P = 0.032). Additionally, among females, significant associations were observed between serum Klotho concentration and speech-frequency PTA (ß = -1.648, 95% CI: -3.197, -0.099; P = 0.037) as well as high-frequency PTA (ß = -3.046; 95% CI: -5.319, -0.772; P = 0.009). Finally, the results of smooth curve fitting and threshold effect analyses indicated a potential negative linear correlation between serum Klotho concentration and PTA thresholds. In conclusion, a lower level of serum Klotho was found to be associated with increased hearing thresholds, particularly among the elderly population. This finding has significant implications for the prevention and treatment of hearing damage.


Assuntos
Perda Auditiva , Proteínas Klotho , Idoso , Feminino , Humanos , Audiometria de Tons Puros/métodos , Perda Auditiva/diagnóstico , Perda Auditiva/metabolismo , Hipertensão , Ruído/efeitos adversos , Inquéritos Nutricionais , Proteínas Klotho/sangue , Proteínas Klotho/química , Biomarcadores
18.
Ear Hear ; 44(5): 1240-1250, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37287104

RESUMO

OBJECTIVES: Childhood hearing loss has well-known lifelong consequences. Certain rural populations are at higher risk for infection-related hearing loss. For Alaska Native children, historical data on hearing loss prevalence suggest a higher burden of infection-related hearing loss, but updated prevalence data are urgently needed in this high-risk population. DESIGN: Hearing data were collected as part of two school-based cluster-randomized trials in 15 communities in rural northwest Alaska over two academic years (2017-2019). All enrolled children from preschool to 12th grade were eligible. Pure-tone thresholds were obtained using standard audiometry and conditioned play when indicated. The analysis included the first available audiometric assessment for each child (n = 1634 participants, 3 to 21 years), except for the high-frequency analysis, which was limited to year 2 when higher frequencies were collected. Multiple imputation was used to quantify the prevalence of hearing loss in younger children, where missing data were more frequent due to the need for behavioral responses. Hearing loss in either ear was evaluated using both the former World Health Organization (WHO) definition (pure-tone average [PTA] > 25 dB) and the new WHO definition (PTA ≥ 20 dB), which was published after the study. Analyses with the new definition were limited to children 7 years and older due to incomplete data obtained on younger children at lower thresholds. RESULTS: The overall prevalence of hearing loss (PTA > 25 dB; 0.5, 1, 2, 4 kHz) was 10.5% (95% confidence interval [CI], 8.9 to 12.1). Hearing loss was predominately mild (PTA >25 to 40 dB; 8.9%, 95% CI, 7.4 to 10.5). The prevalence of unilateral hearing loss was 7.7% (95% CI, 6.3 to 9.0). Conductive hearing loss (air-bone gap of ≥ 10 dB) was the most common hearing loss type (9.1%, 95% CI, 7.6 to 10.7). Stratified by age, hearing loss (PTA >25 dB) was more common in children 3 to 6 years (14.9%, 95% CI, 11.4 to 18.5) compared to children 7 years and older (8.7%, 95% CI, 7.1 to 10.4). In children 7 years and older, the new WHO definition increased the prevalence of hearing loss to 23.4% (95% CI, 21.0 to 25.8) compared to the former definition (8.7%, 95% CI, 7.1 to 10.4). Middle ear disease prevalence was 17.6% (95% CI, 15.7 to 19.4) and was higher in younger children (23.6%, 95% CI, 19.7 to 27.6) compared to older children (15.2%, 95% CI, 13.2 to 17.3). High-frequency hearing loss (4, 6, 8kHz) was present in 20.5% (95% CI, 18.4 to 22.7 [PTA >25 dB]) of all children and 22.8% (95% CI, 20.3 to 25.3 [PTA >25 dB]) and 29.7% (95% CI, 27.0 to 32.4 [PTA ≥ 20 dB]) of children 7 years and older (limited to year 2). CONCLUSIONS: This analysis represents the first prevalence study on childhood hearing loss in Alaska in over 60 years and is the largest cohort with hearing data ever collected in rural Alaska. Our results highlight that hearing loss continues to be common in rural Alaska Native children, with middle ear disease more prevalent in younger children and high-frequency hearing loss more prevalent with increasing age. Prevention efforts may benefit from managing hearing loss type by age. Lastly, continued research is needed on the impact of the new WHO definition of hearing loss on field studies.


Assuntos
Surdez , Perda Auditiva de Alta Frequência , Criança , Humanos , Pré-Escolar , Adolescente , Alaska/epidemiologia , Prevalência , População Rural , Audiometria de Tons Puros/métodos
19.
Brain Struct Funct ; 228(6): 1511-1534, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37349539

RESUMO

Tinnitus is one of the main hearing impairments often associated with pure-tone hearing loss, and typically manifested in the perception of phantom sounds. Nevertheless, tinnitus has traditionally been studied in isolation without necessarily considering auditory ghosting and hearing loss as part of the same syndrome. Hence, in the present neuroanatomical study, we attempted to pave the way toward a better understanding of the tinnitus syndrome, and compared two groups of almost perfectly matched individuals with (TIHL) and without (NTHL) pure-tone tinnitus, but both characterized by pure-tone hearing loss. The two groups were homogenized in terms of sample size, age, gender, handedness, education, and hearing loss. Furthermore, since the assessment of pure-tone hearing thresholds alone is not sufficient to describe the full spectrum of hearing abilities, the two groups were also harmonized for supra-threshold hearing estimates which were collected using temporal compression, frequency selectivity und speech-in-noise tasks. Regions-of-interest (ROI) analyses based on key brain structures identified in previous neuroimaging studies showed that the TIHL group exhibited increased cortical volume (CV) and surface area (CSA) of the right supramarginal gyrus and posterior planum temporale (PT) as well as CSA of the left middle-anterior part of the superior temporal sulcus (STS). The TIHL group also demonstrated larger volumes of the left amygdala and of the left head and body of the hippocampus. Notably, vertex-wise multiple linear regression analyses additionally brought to light that CSA of a specific cluster, which was located in the left middle-anterior part of the STS and overlapped with the one found to be significant in the between-group analyses, was positively associated with tinnitus distress level. Furthermore, distress also positively correlated with CSA of gray matter vertices in the right dorsal prefrontal cortex and the right posterior STS, whereas tinnitus duration was positively associated with CSA and CV of the right angular gyrus (AG) and posterior part of the STS. These results provide new insights into the critical gray matter architecture of the tinnitus syndrome matrix responsible for the emergence, maintenance and distress of auditory phantom sensations.


Assuntos
Perda Auditiva , Zumbido , Humanos , Encéfalo/diagnóstico por imagem , Audição , Comorbidade , Audiometria de Tons Puros/métodos , Limiar Auditivo
20.
Adv Gerontol ; 36(2): 265-273, 2023.
Artigo em Russo | MEDLINE | ID: mdl-37356105

RESUMO

The aim of the study is to evaluate the possibility to implement machine learning to create a digital auditory profile for elderly patients and to analyze the hearing aid fitting efficacy depending on involvement of the peripheral and central auditory pathways in a pathological process. Data analysis of 375 people aged 60-93 years is presented. 355 patients with chronic bilateral hearing loss (230 of them used hearing aids) were included in the main group, and 20 normal hearing elderly people were included in the control group. Audiological examination consisted of standard tests (pure tone audiometry, impedancemetry, speech audiometry in quiet) and tests to evaluate the central auditory processing (binaural fusion, dichotic digits, speech audiometry in noise, random gap detection). The Montreal Cognitive Assessment was used to detect cognitive impairment. The hearing aid fitting efficiency was evaluated with COSI questionnaire and speech audiometry in free field. Processing of the results was carried out using Pearson's correlation analysis aimed at creating a polynomial model of a patient's hearing on the basis of the limited test battery. There were close correlations between the state of cognitive functions and age, results of tests to evaluate the central auditory processing, as well as patients' satisfaction of hearing aid. The results of the work indicate the possibility of using computer technologies of data analysis to develop rehabilitation programs for elderly hearing impaired patients.


Assuntos
Auxiliares de Audição , Perda Auditiva , Idoso , Humanos , Perda Auditiva/diagnóstico , Perda Auditiva/etiologia , Perda Auditiva/reabilitação , Percepção Auditiva , Audiometria de Tons Puros/métodos , Audiometria da Fala
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...